![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1937663.1 : SL3000 - ACSLS Hanging After Library Reconfiguration
In this Document
Applies to:Sun StorageTek SL3000 Modular Library System - Version All Versions and laterInformation in this document applies to any platform. There has been 2 recent events after upgrading or relocating SL3000s that involved ACSLS support over many hours to resolve. It required dropping of database tables, rebuilding the database and then running an acsss_config in addition to multiple reboots and ACSLS shutdowns and restarts. SymptomsACSLS Hanging After Library Reconfiguration ChangesUpgraded or Relocated SL3000. CauseThe source of the problem was the presence of data cartridges in reserved or inactive cells when ACSLS was started. SolutionMake sure that when bulk loading the library that the customer is aware of the cells that are not available.
Attachments This solution has no attachment |
||||||||||||||||||
|