Solution Type  Problem Resolution Sure

Solution  1937240.1 :   T10000B - 0113 SNO  


Related Items
  • Sun StorageTek T10000B Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Cause
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for service personnel
Created from <SR 3-9727548670>

Applies to:

Sun StorageTek T10000B Tape Drive - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Symptoms

0113 SNO Condition

Cause

This problem can be caused by bit flips in the drive. This is typically a rare condition that you see once and then may nver see it again.

FSC Dictionary Description:
MODEL = T10000B
FSC = 0113
(FSC Match Found in Rev. 1.50)


FSC: 0113 KS_TIMER_CONTROL_SET_IIP

MIM Code: INOPERABLE

FRU: MICROCODE CONF: 100%

Summary: |INVALID UCODE |PARAMETER PASSED| *** |

Field Text:
Invalid parameter for clock ticks to set.  

Solution

Upload the dump from the drive SNO to see if it is a bit flip. If a drive is seeing many of these then replace the drive.
 