Asset ID: |
1-72-1937240.1 |
Update Date: | 2017-09-20 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1937240.1
:
T10000B - 0113 SNO
Related Items |
- Sun StorageTek T10000B Tape Drive
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for service personnel
Created from <SR 3-9727548670>
Applies to:
Sun StorageTek T10000B Tape Drive - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
Symptoms
0113 SNO Condition
Cause
This problem can be caused by bit flips in the drive. This is typically a rare condition that you see once and then may nver see it again.
FSC Dictionary Description:
MODEL = T10000B
FSC = 0113
(FSC Match Found in Rev. 1.50)
FSC: 0113 KS_TIMER_CONTROL_SET_IIP
MIM Code: INOPERABLE
FRU: MICROCODE CONF: 100%
Summary: |INVALID UCODE |PARAMETER PASSED| *** |
Field Text:
Invalid parameter for clock ticks to set.
Solution
Upload the dump from the drive SNO to see if it is a bit flip. If a drive is seeing many of these then replace the drive.
References
<BUG:19814640> - SOCIAL SECURITY ADMIN - 0113 SNO
Attachments
This solution has no attachment