Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1936328.1
Update Date:2017-08-16
Keywords:

Solution Type  Problem Resolution Sure

Solution  1936328.1 :   SL8500 - SDP Alert RC=1306 PTP Hardware Failure  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Symptoms
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for Service Personnel
Created from <SR 3-9704475337>

Applies to:

Sun StorageTek SL8500 Modular Library System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

PTP= Pass Thru Port
SDP= Service Delivery Platform
RC= Result Code

Symptoms

SDP generated 1306 PTP hardware failure alert received.

RC1306

Cause

 Defective PTP assembly.

Solution

 How to Remove / Replace the Pass-Thru Port ( PTP ) Mechanism in SL8500 Library:ATR:1368301.1:2


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.