Asset ID: |
1-72-1935272.1 |
Update Date: | 2017-12-05 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1935272.1
:
SL150 - Network Configuration Conflict - Use of 192.168.10.x On Network Port1
Related Items |
- StorageTek SL150 Modular Tape Library
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL150 Library
|
SL150 do not configure management network(Network Port 1) into subnet: 192.168.10.x.
As this overlaps with Network Port 2 default and hard coded IP: 192.168.10.10/24
In this Document
Created from <SR 3-9538495141>
Applies to:
StorageTek SL150 Modular Tape Library - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Symptoms
SL150 do not configure management network(Network Port 1) into subnet: 192.168.10.x.
As this overlaps with Network Port 2 default and hard coded IP: 192.168.10.10/24
You will end up in a situation where port 1 will respond to 192.168.10.10 and port 2 will not. Also other odd behavior might appear.
Changes
In case you don't have port 2 enabled, this is probably not an issue, but to avoid problems, do not use 192.168.10.x IP range with port 1.
Cause
This is related to the HW design of the SL150 network ports and cannot be changed.
Solution
Change network port1 IP address to something else than 192.168.10.x
References
<BUG:15784776> - SUNBT7160463 SL150 NETWORK CONFIGURATION CONFLICT IN 0011 (0.13.00) CODE
Attachments