Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1934564.1
Update Date:2016-11-04
Keywords:

Solution Type  Problem Resolution Sure

Solution  1934564.1 :   Measurements For Deleted Associations Still Showing In Measurement Files  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-9687079151>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 45.0 to EAGLE 46.0 [Release EAGLE 45.0 to EAGLE 46.0]
Information in this document applies to any platform.

Symptoms

 1. We have noticed that in the measurement files, the statistics for deleted associations are still showing:

"STATUS","ASSOC","ECASNEST","DURASNEST","DATCHKSN","RTXCHNKS","DATCHKRC","SCPKTSNT","SCPKTRCV","SCOCTSNT","SCOCTRCV","CNTLCHKS","ORDCHKSN","CNTLCHKR","ORDCHKRC","GAPACKSR","ASOCABTD","ASOCSHTD","PEERFAIL","ASMAXRTO"
"I","xxxpoc",0,900,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0
"N","xxxtitantst", , , , , , , , , , , , , , , , , ,
"N","xxxsmsx1", , , , , , , , , , , , , , , , , ,
"N","xxxsmsx2", , , , , , , , , , , , , , , , , ,
"I","xxxwcssim3",0,0,3551,0,3649,6379,6523,704392,674960,4089,3551,4017,3649,0,0,0,0,518

2. Additionally, the information for the other associations is being marked as "I" instead of "K".

Cause

1. Title: Associations deleted from system in past still appear in the comp-sctpasoc Comma Separated Values (CSV) reports

PR: 231613 (BUG 19106690)

Each 30 minutes interval, Stream Control Transmission Protocol (SCTP) associations measurements are written to disk using an index.

- This index is not sequential so the entries are scattered throughout the table, anywhere from 0 to the total number of valid SCTP associations entities.
- The set of measurements that were collected 24 hours ago still exists in the meas table (on the disk).

The reporting algorithm simply searches for non-zero timestamps from 0 to the total number of valid SCTP associations entities.

  - If the association is still provisioned, the new data will overwrite the old data because the index will remain the same.
  - If an entry has been deleted, nothing will be written at that index, leaving the old entry intact.

Even though the timestamp has expired, it is non-zero and thus picked up by the reporting function.
 

2. The associations measurement reports with E5-OAM Integrated Measurements shows Incomplete (I) status:

PR: 234507 (BUG 19110446)

Cause:
Counter is not updated to 900 seconds (15 minutes interval) reporting the measurement as incomplete (I).

 

Solution

 This two issues are fixed on EAGLE R46.0 which is Generally Available (GA).

References

<BUG:19110446> - [234507]15 MINUTES MEASUREMENTS REPORTS WITH E5-OAM INTEGRATED SHOWS INCOMPLETE
<BUG:19106690> - [231613]ASSOCIATIONS DELETED FROM SYSTEM IN PAST STILL APPEAR IN THE COMP-SCTPAS