![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1932651.1 : OAKD Does Not Start After Upgrading to ODA 12.1.2 with Messages Checking/Waiting for ACFS /odadatafs
In this Document
Created from <SR 3-9684521231> Applies to:Oracle Database Appliance - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsAfter upgrading to ODA 12.1.2 version, oakd daemon does not start and all the oakcli commands fails with following error: Failed to connect to oakd.
The oakd log shows following messages: 2014-10-03 06:27:45.170888626init.oak]Starting oakd..]
2014-10-03 06:27:45.217: [ OAKFW][4020438592] Logging level for Module: allcomp 0 2014-10-03 06:27:45.217: [ OAKFW][4020438592] Logging level for Module: default 0 2014-10-03 06:27:45.217: [ OAKFW][4020438592] Logging level for Module: OAKFW 1 2014-10-03 06:27:45.217: [ OAKFW][4020438592] Logging level for Module: OAKD 1 2014-10-03 06:27:45.217: [ OAKFW][4020438592] Logging level for Module: OAKHW 1 2014-10-03 06:27:45.217: [ OAKFW][4020438592] Logging level for Module: ADAPTER 1 2014-10-03 06:27:45.217: [ OAKFW][4020438592] Logging level for Module: CLSFRAME 0 2014-10-03 06:27:45.217: [ OAKFW][4020438592] Logging level for Module: CRSCOMM 0 2014-10-03 06:27:45.217: [ OAKFW][4020438592] Logging level for Module: CRSTIMER 0 2014-10-03 06:27:45.217: [ OAKFW][4020438592] Starting /opt/oracle/oak/log/dsrcdb21/oak 2014-10-03 06:27:45.217: [ OAKFW][4020438592] ORA_CRS_HOME = /u01/app/12.1.0.2/grid/ 2014-10-03 06:27:45.217: [ OAKFW][4020438592] ORACLE_HOME = /u01/app/12.1.0.2/grid/ 2014-10-03 06:27:45.217: [ OAKFW][4020438592] Checking/Waiting for CRS ... 2014-10-03 06:27:47.244: [ OAKFW][4020438592] The current CRS version is 12.1.0.2.0 2014-10-03 06:27:47.244: [ OAKFW][4020438592] CRS detected ! 2014-10-03 06:27:47.244: [ OAKFW][4020438592] Checking/Waiting for ACFS /odadatafs ... 2014-10-03 06:28:47.251: [ OAKFW][4020438592] Checking/Waiting for ACFS /odadatafs ... 2014-10-03 06:29:47.259: [ OAKFW][4020438592] Checking/Waiting for ACFS /odadatafs ... 2014-10-03 06:30:47.266: [ OAKFW][4020438592] Checking/Waiting for ACFS /odadatafs ... 2014-10-03 06:31:47.274: [ OAKFW][4020438592] Checking/Waiting for ACFS /odadatafs .. Time out: Failed to detect ODADATAFS
ChangesUpgraded Infra and GI to ODA 12.1.2.0.0 CauseThis is due to bug : Bug 18996124 - LNX64-121-CMT: AFTER GI PATCH, OAKD IN FOREGROUND MODE,FAILED TO CONNECT TO OAKD which is closed as duplicate of : BUG 18977793 - LNX64-121-CMT: WARNING IN POSTPATH -V 12.1.2.0.0 --GI (PERMISSION DENIED) Due to bug 18977793, ODADATAFS is not configured. SolutionODADATAFS is configured as post patch steps in GI upgrade. Please run following to resolve the issue: As a root user rerun the GI upgrade: # oakcli update -patch 12.1.2.0.0 --gi or # /opt/oracle/oak/pkgrepos/System/12.1.2.0.0/bin/postpatch -v 12.1.2.0.0 --gi Note: The example above is for 12.1.2.0.0 -- Match the version.patchset level based on actual version used
References<BUG:18977793> - LNX64-121-CMT: WARNING IN POSTPATH -V 12.1.2.0.0 --GIAttachments This solution has no attachment |
||||||||||||||||||||
|