Solution Type  Problem Resolution Sure

Solution  1932651.1 :   OAKD Does Not Start After Upgrading to ODA 12.1.2 with Messages Checking/Waiting for ACFS /odadatafs  


Related Items
  • Oracle Database Appliance
  •  
Related Categories
  • PLA-Support>Eng Systems>Exadata/ODA/SSC>Oracle Database Appliance>DB: ODA_EST
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-9684521231>

Applies to:

Oracle Database Appliance - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

After upgrading to ODA 12.1.2 version, oakd daemon does not start and all the oakcli commands fails with following error:

Failed to connect to oakd.

 The oakd log shows following messages:

2014-10-03 06:27:45.170888626init.oak]Starting oakd..]
2014-10-03 06:27:45.217: [ OAKFW][4020438592] Logging level for Module: allcomp 0
2014-10-03 06:27:45.217: [ OAKFW][4020438592] Logging level for Module: default 0
2014-10-03 06:27:45.217: [ OAKFW][4020438592] Logging level for Module: OAKFW 1
2014-10-03 06:27:45.217: [ OAKFW][4020438592] Logging level for Module: OAKD 1
2014-10-03 06:27:45.217: [ OAKFW][4020438592] Logging level for Module: OAKHW 1
2014-10-03 06:27:45.217: [ OAKFW][4020438592] Logging level for Module: ADAPTER 1
2014-10-03 06:27:45.217: [ OAKFW][4020438592] Logging level for Module: CLSFRAME 0
2014-10-03 06:27:45.217: [ OAKFW][4020438592] Logging level for Module: CRSCOMM 0
2014-10-03 06:27:45.217: [ OAKFW][4020438592] Logging level for Module: CRSTIMER 0
2014-10-03 06:27:45.217: [ OAKFW][4020438592] Starting /opt/oracle/oak/log/dsrcdb21/oak
2014-10-03 06:27:45.217: [ OAKFW][4020438592] ORA_CRS_HOME = /u01/app/12.1.0.2/grid/
2014-10-03 06:27:45.217: [ OAKFW][4020438592] ORACLE_HOME = /u01/app/12.1.0.2/grid/
2014-10-03 06:27:45.217: [ OAKFW][4020438592] Checking/Waiting for CRS ...
2014-10-03 06:27:47.244: [ OAKFW][4020438592] The current CRS version is 12.1.0.2.0
2014-10-03 06:27:47.244: [ OAKFW][4020438592] CRS detected !
2014-10-03 06:27:47.244: [ OAKFW][4020438592] Checking/Waiting for ACFS /odadatafs ...
2014-10-03 06:28:47.251: [ OAKFW][4020438592] Checking/Waiting for ACFS /odadatafs ...
2014-10-03 06:29:47.259: [ OAKFW][4020438592] Checking/Waiting for ACFS /odadatafs ...
2014-10-03 06:30:47.266: [ OAKFW][4020438592] Checking/Waiting for ACFS /odadatafs ...
2014-10-03 06:31:47.274: [ OAKFW][4020438592] Checking/Waiting for ACFS /odadatafs ..
Time out: Failed to detect ODADATAFS 

 

Changes

 Upgraded Infra and GI to ODA 12.1.2.0.0

Cause

This is due to bug :

Bug 18996124 - LNX64-121-CMT: AFTER GI PATCH, OAKD IN FOREGROUND MODE,FAILED TO CONNECT TO OAKD

which is closed as duplicate of :

BUG 18977793 - LNX64-121-CMT: WARNING IN POSTPATH -V 12.1.2.0.0 --GI (PERMISSION DENIED) 

Due to bug 18977793, ODADATAFS  is not configured.

Solution

 ODADATAFS is configured as post patch steps in GI upgrade. 

Please run following to resolve the issue:

As a root user rerun the GI upgrade:

# oakcli update -patch 12.1.2.0.0 --gi

or 

# /opt/oracle/oak/pkgrepos/System/12.1.2.0.0/bin/postpatch -v 12.1.2.0.0 --gi

Note:  The example above is for 12.1.2.0.0 -- Match the version.patchset level based on actual version used 
                oakcli update -patch 12.1.2.x.0 --gi            where "x" is the patchset level   
            Other versions available include                    12.1.2.1.0 or 12.1.2.2.0 or 12.1.2.3.0

  


Once this completes it will give message that oakd started. After this all the commands will work fine.