Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1932500.1
Update Date:2016-02-25
Keywords:

Solution Type  Problem Resolution Sure

Solution  1932500.1 :   Oracle ZFS Storage Appliance: Disk Tray DE2-24C/DE2-24P Hex Display Not Showing 00  


Related Items
  • Sun ZFS Storage 7320
  •  
  • Oracle ZFS Storage ZS3-2
  •  
  • Oracle ZFS Storage ZS3-4
  •  
  • Sun ZFS Storage 7420
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: 7xxx NAS
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-9673564591>

Applies to:

Sun ZFS Storage 7320 - Version All Versions to All Versions [Release All Releases]
Sun ZFS Storage 7420 - Version All Versions to All Versions [Release All Releases]
Oracle ZFS Storage ZS3-2 - Version All Versions to All Versions [Release All Releases]
Oracle ZFS Storage ZS3-4 - Version All Versions to All Versions [Release All Releases]
7000 Appliance OS (Fishworks)

Symptoms

The hex display is showing any number other than (the default) "00"

Cause

There is a problem with the display hardware itself.

NOTE: The hex display is NOT used to display any error condition and has NO current use in this product and there are NO definitions for any number displayed on it.

 

Solution

Repair the chassis hardware related to the hex display.

There is a ribbon cable involved and typically reseating this cable connection from the status panel to the midplane resolves this - such that the display is again displaying "00".

 

NOTE: The above procedure should be carried out by an Oracle Field Service Engineer.  Downtime may be required.

 

Reference:  https://mosemp.us.oracle.com/handbook_internal/Devices/Wiring_Dgms/WIR_DE2_24C.html

If there is physical damage or the issue persists, then replace the chassis/midplane.
FRU P/Ns:
 DE2-24C: 7044319
 DE2-24P: 7043630
 DE2-24P NEBS: 7078863

Reference:
 How to replace a DE2-24C/P Drive Tray Chassis in a ZFSSA 7320/7420 or ZS3-system:ATR:1646100.1:2(Doc ID 1646100.1)

 

 

References

<BUG:16939914> - DE2-24-C TRAY SHOWING ABNORMAL STATE ON TRAY INDICATOR
<NOTE:1646100.1> - How To Replace A DE2-24C/P Drive Tray Chassis In A ZFSSA 7320/7420 Or ZS3/4-System:ATR:1646100.1:2

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback