Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1932109.1
Update Date:2014-10-03
Keywords:

Solution Type  Problem Resolution Sure

Solution  1932109.1 :   ODA: Message: "Connection With SP Is Down, Please Try Redirection Later" During Bare-Metal Restore  


Related Items
  • Oracle Database Appliance X3-2
  •  
  • Oracle Database Appliance X4-2
  •  
Related Categories
  • PLA-Support>Eng Systems>Exadata/ODA/SSC>Oracle Database Appliance>DB: ODA_EST
  •  


Attempted connection to ILOM gives: ""Connection With SP Is Down, Please Try Redirection Later."

Created from <SR 3-9655008721>

Applies to:

Oracle Database Appliance X4-2 - Version All Versions and later
Oracle Database Appliance X3-2 - Version All Versions and later
Information in this document applies to any platform.

Symptoms

During the process of performing a bare-metal restore on our ODA system, there was a power disruption.

We started over to avoid the resulting issues, but now we are getting a message:

"Cannot redirect CD-ROM image, Connection with SP is down, please try redirection later."

Cause

power interruption has put the ILOM into a intermediate or unknown state
 

Solution


reset the ILOM Service Processor for the node

How to Reboot the Service Processor (SP) on x86 Platforms. [Doc ID 1448038.1]

References

<NOTE:1448038.1> - How to Reboot the Service Processor (SP) on x86 Platforms.

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.