![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1931857.1 : SL150 - Robotics Not Working - Drives Can Be Seen By the Backup Server But Library Can Not Be Seen
In this Document
Created from <SR 3-9668756811> Applies to:StorageTek SL150 Modular Tape Library - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsSL150 robotics not working. CauseRobot can not be seen by the backup server but drives can be seen. SolutionPhysically swap drives 0 and 1. References<NOTE:1641405.1> - SL150 - Reporting No Boot Device Detected<NOTE:1533738.1> - SL150 - Fibre Channel Library Can Not Be Recognized by Server After Reboot <NOTE:1552924.1> - SL150 - Library Cannot be Seen by Net Backup, Drives Can be Seen, Robtest Cannot See the TLD Device Attachments This solution has no attachment |
||||||||||||||||||
|