Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1931837.1
Update Date:2017-08-16
Keywords:

Solution Type  Problem Resolution Sure

Solution  1931837.1 :   SL8500 - Display of ILC Shows Incorrect State  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Symptoms
Changes
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for Service Personnel

Applies to:

Sun StorageTek SL8500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.

Symptoms

In 8.35 code it was noticed that a "config ilc print" command displays the port as "down".  The state from config ilc print should show the physical state UP (connected) Down (not connected).

Changes

Firmware update to 8.35

Cause

There is a bug where we are showing down if the port is connected to SDP or some other device and not connected to another library.

Solution

  In a library complex the displayed state should be correct.

SL8500> config ilc print
   requestId
   requestId 628301
   Attributes Configuration enabled
              Status        DOWN

   Object     Ilc Astate
   Done
   Failure Count 0
   Success Count 1

COMPLETED
SL8500>

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.