Solution  1929585.1 :   SL150 - Equipment Inoperable State, Fault Code 9104, 9114  


Related Items
  • StorageTek SL150 Modular Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL150 Library
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-9632172800>

Applies to:

StorageTek SL150 Modular Tape Library - Version All Versions and later
Information in this document applies to any platform.

Symptoms

ROBOT_UNSPECIFIED_FAILURE - Fault Code:9114

ROBOT_REACH_MOVE_ERROR - Fault Code:9104

Equipment Inoperable State

Cause

Inoperable robot module.

Solution

Replace defective robotic module.

SL150 - How to Remove/Replace the Robot CRU in a StorageTek SL150 Modular Tape Library:ATR:1473774.1:0 (Doc ID 1473774.1)

 

7023260 [C] Robot Module  
7040176 [C] Robot Module  


References

<NOTE:1605188.1> - SL150 - Fails to Initialize on Start Up, Fault Code: 9104 Robot Initialization Error
<NOTE:1473774.1> - SL150 - How to Remove/Replace the Robot CRU in a StorageTek SL150 Modular Tape Library:ATR:1473774.1:0