Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1929447.1
Update Date:2016-05-26
Keywords:

Solution Type  Problem Resolution Sure

Solution  1929447.1 :   ibstatus output shows state:init  


Related Items
  • Exadata X3-2 Quarter Rack
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Sun Network Infiniband
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-9598120868>

Applies to:

Exadata X3-2 Quarter Rack - Version All Versions and later
Information in this document applies to any platform.

Symptoms

cellnode1#ibstatus command shows that the INIT state:

Infiniband device 'mlx4_0' port 2 status:
default gid: fe80:0000:0000:0000:0010:e000:0133:14ff
base lid: 0x29
sm lid: 0x22
state: 2: INIT<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<< This port does not see the SM (Subnet Master)
phys state: 5: LinkUp<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<< Cable is connected and there is a link
rate: 40 Gb/sec (4X QDR)
link_layer: IB

Cause

 There were no subnetmanagers MASTER (SM) running on the IB fabric.

Solution

Collect ILOM snapshots from all IB switches on the Infiniband fabric and contact Oracle support.

Alternatively, customer can manually login to all the IB switches and check:

# ibswitches

# getmaster

 




Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.