![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1929335.1 : SL150 - If Port-1 IP is Configured as 192.168.10.x/24 and Port-2 Access Enabled, 'Ping' Works to Port-1 Using Port-2's IP Address
In this Document
Created from <SR 3-9535704591> Applies to:StorageTek SL150 Modular Tape Library - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsSL150 ping works port-1 using port1 and port-2 IPs with the below configuration. Port1:192.168.10.1/24 Port2:192.168.10.10/24 (Fixed) PC:192.168.10.2/24 PC--SL150(Port1) Crossover cable direct connection. Ping works to 192.168.10.1 and 192.168.10.10. ChangesConfigured port-1 IP to 192.168.0.1/24 and enabled port-2 access. CauseIt is possible to configure the same subnet for port-1 as for port-2 i.e. 192.168.0.x/24. This causes a conflict. Confirmed code level 225 has fixed IP 192.168.10.10/24 for port-2. SolutionIt is required to configure the IP address of port-1 to other than 192.168.10.x/24 to avoid IP conflict with port-2. This is not mentioned in published documents. Attachments This solution has no attachment |
||||||||||||||||||
|