Solution Type Problem Resolution Sure Solution 1928820.1 : T10000A - Reporting Drive SNO FSC 304D
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun StorageTek T10000A Tape Drive - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsDrive is seen to be with the latest microcode.This FSC is to be fixed with 1.48.x05 or higher code. CauseThe dump shows dmod 2057 has offtrack problems on both heads. This is likely a roller problem. The drive needs to be replaced. The 304d sno results from an unexpected UNLOAD_COMPLETE message arriving after the unload operation was halted. SolutionReplacing the drive should resolve this issue.