Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1928820.1
Update Date:2017-09-21
Keywords:

Solution Type  Problem Resolution Sure

Solution  1928820.1 :   T10000A - Reporting Drive SNO FSC 304D  


Related Items
  • Sun StorageTek T10000A Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: From oracle bug
Created from <SR 3-9617485303>

Applies to:

Sun StorageTek T10000A Tape Drive - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

Drive is seen to be with the latest microcode.This FSC is to be fixed with 1.48.x05 or higher code.

   Drive: 531002002057
   T10000A   Version: 1.50.103


Interface Type: FIBRE

Drive SNO FSC is 304d
(FSC Exact Match Found)
FSC: 304D HS_FSC_UTIL_PAE_UNKNOWN_MSG
MIM Code: INOPERABLE

FRU: MICROCODE   CONF: 95%
FRU: HARDWARE   CONF: 5%

Summary: |INVALID UCODE   |MESSAGE RECEIVED| ***            |

Field Text:
Illegal message received

Cause

The dump shows dmod 2057 has offtrack problems on both heads. This is likely a roller problem. The drive needs to be replaced. The 304d sno results from an unexpected UNLOAD_COMPLETE message arriving after the unload operation was halted.

Solution

Replacing the drive should resolve this issue.

 