Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1928576.1
Update Date:2016-05-26
Keywords:

Solution Type  Problem Resolution Sure

Solution  1928576.1 :   Steps to fix the same port on both IB leaf switches (ib2 and ib3) being down.  


Related Items
  • Exadata X3-2 Hardware
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Sun Network Infiniband
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-9585280282>

Applies to:

Exadata X3-2 Hardware - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

ibqueryerror.pl output shows symbol err and link down on both ports that connect to the same host.

IB2# ibqueryerrors.pl -rR -s RcvSwRelayErrors,XmtDiscards,XmtWait,VL15Dropped
Suppressing: RcvSwRelayErrors,XmtDiscards,XmtWait,VL15Dropped
Errors for 0x00212ff5673da0a0 ""
GUID 0x00212ff5673da0a0 port 10: [SymbolErrors == 65535] [LinkDowned == 1]
Link info: 2 10[ ] ==( 4X 2.5 Gbps)==> (Disconnected)
Errors for 0x002128f5672da0a0 ""
GUID 0x002128f5672da0a0 port 10: [SymbolErrors == 65535] [LinkDowned == 1] [LinkRecovers == 1]
Link info: 1 10[ ] ==( 4X 2.5 Gbps)==> (Disconnected)

Listlinkup on both IB2 and IB3 show the following:
Connector 13B Present <-> Switch Port 10 is down (Enabled)

Cause

In this case, the HCA in question had failed, so both IB links were in DOWN state.

Solution

One approach is to replace IB cables, but in this case, the HCA in question had failed and needed to be replaced.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback