Customer reported all drives are offline to NBU. When viewing the SLCosole there was no drive folder.

In this Document
Symptoms
Changes
Cause
Solution
 Troubleshooting Steps
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for service personnel

Applies to:

Sun StorageTek SL3000 Modular Library System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

NBU = Net BackUp

This issue occurred in a SL3000 that had been running for a time.
Library was showing offline from the console.

3-9599659211

Symptoms

Customer reported all drives are offline to NBU. When viewing the SLConsole there was no drive folder.

Log Snapshot does NOT report any errors on the library.
The Drive Folder does NOT show up in SL Console.
Unable to ping the HBT from the CLI Port. 

Changes

 None

Cause

 Defective component on the PUM Motherboard.

Solution

Determine if the internal switch to the HBT on the motherboard PUM card is defective.

Troubleshooting Steps

1. Initiate a SSH session to the SL3000 via the serial port.

2. Issue a "ping hbt" command via the Command Line Interface.  If Redundant Electronics is installed you will need to enter a "ping hbta" command.

Output should look like the following if successful:

SL3000> ping hbta
  PING hbta (10.0.0.11): 56 data bytes
  64 bytes from 10.0.0.11: icmp_seq=0 ttl=255 time=1.6 ms

If not successful you will see this output:

SL3000> ping hbt
  PING hbt (10.0.0.10): 56 data bytes

  --- hbt ping statistics ---
  1 packets transmitted, 0 packets received, 100% packet loss
COMPLETED

3. Check the LED indicators on the PUM card.  Refer to the attached file for further LED information.

4. If the 4th to the left indicator is off (HBTA INT), then the internal switch on the PUM is probably defective.  The PUM will need to be replaced.

   SL3000 - How to Remove and Replace the PUM card (Doc ID 1927365.1)