Solution Type  Problem Resolution Sure

Solution  1926637.1 :   LTO4 - Drive Disappeared From SL8500 Library  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
  • IBM LTO4 Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-9570578031>

Applies to:

Sun StorageTek SL8500 Modular Library System - Version All Versions to All Versions [Release All Releases]
IBM LTO4 Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

LTO drive has disappeared and we are unable to see the drive details in SL console

Log symptoms :

1118 - (46X)
No drive installed at address, hliLsm=2 address=(Drive_Bay32)1,3,-2,1,1
(Errors Started - 2014-09-04 00:12:48 Errors Stopped - 2014-09-05 15:24:06)

1301 - (2X)
Device response time-out, request=  getState  Internal   1,3,-2,1,1    address = Drive_Bay32(1,3,-2,1,1)
Device response time-out, request=  controlPower  Internal   1,3,-2,1,1  on    address = Drive_Bay32(1,3,-2,1,1)
(Errors Started - 2014-09-01 11:38:40 Errors Stopped - 2014-09-01 11:51:14)

1303 - (1X)
Failure from drive Code: 000 - ok,
(Errors Started - 2014-09-01 11:39:14 Errors Stopped - 2014-09-01 11:39:14)


Changes

 

Cause

Drive bezel, Drive tray power supply, cable assembly (TTI), PWA, HBD Card, Drive Tray

Solution

Check the drive latch is locked properly and drive seated properly
Confirm that the drive bezel is correctly seated and is not broken.
Check TTI cable connectivity.
Check drive tray power supply LED is blinking green.

Swap the drive with other working drive tray.

If the drive is working on another drive tray try replacing the HBD at the faulty location.
If the drive is not working on another drive tray replace the drive.

Check whether the drive visible from SLC console.


 