Asset ID: |
1-72-1926049.1 |
Update Date: | 2017-09-26 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1926049.1
:
T10000B - FSC36E5: Automatic ASR Creation From MDVOP
Related Items |
- Sun StorageTek T10000B Tape Drive
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: Remote
|
In this Document
Created from <SR 3-9603167190>
Applies to:
Sun StorageTek T10000B Tape Drive - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
Symptoms
FSC36E5, 36E5
Cause
While attempting to read the MIR, the RO Hardware indicated that the MIR was not completely read while also giving indications that the MIR was successfully read.
Solution
Perform the operation on a different tape and see if the issue would repeat.
Attachments
This solution has no attachment