Symptoms
FSC5E04, 5E04
Cause
FSC Dictionary Description:
MODEL = T10000C
FSC = 5E04
(FSC Match Found in Rev. 1.61)
FSC: 5E04 DIAG_SRV_FSC_CARTRIDGE_PRESENT
MIM Code: NONE
FRU: HARDWARE CONF: 100%
Summary: |INTERCONNECT |ELEVATOR |CARTRIDGE |
Field Text:
A diagnostic command was issued while a cartridge was present.
Engineering Text:
A diagnostic command was issued while a cartridge was present. Detected by: diag_srv_s_mc.c
Solution
This may indicate that the drive IPLed and found a tape in it when it came back up.
Attachments