Solution  1922830.1 :   SL8500 - Drive Health State : Error - Failed Target Calibration - Result Code 5416  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-9549385641>

Applies to:

Sun StorageTek SL8500 Modular Library System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

Drive is offline and Health state show as error. However, from drive detail we are able to see the tape drive wwn, code and serial number.

1,3,-2,1,1   2,1,0,0   32   offline   HpUltrium4   HUE1047MMB   H64S-015.021  
 
              Device Id  : 1,3,-2,1,1
             
                 General
                    Drive Type : HpUltrium4
                    Code Version : H64S-015.021
                    Vendor : HP
                    Serial Number : HUE1047MMB
                    Interface Type : Fibre
                 Drive Configuration
                    World Wide Name Node : 50:01:04:f0:00:a1:12:b3
                    Port A World Wide Name : 50:01:04:f0:00:a1:12:b4
                    Port A Enabled : true
                    Port A Loop ID : auto
                    Port A Speed (GB) : 4 GBIT
                    Port A Link status : Initialized
                    Port B World Wide Name : 50:01:04:f0:00:a1:12:b5
                    Port B Enabled : true
                    Port B Loop ID : auto
                    Port B Speed (GB) : N/A
                    Port B Link status : Uninitialized


              Device Id  : 1,3,-2,1,1
             
                 State
                    Health State : error
                    Device State : Error
                    Access State : offline
                    Drive State : empty
                    Drive needs cleaning : false
                    Host Activity : false
                    Drive Tray State : ok
                    Drive Over Temp : false

Getting result code 5416 and robot can not find target.

 

2014-09-01T14:40:23.495,   1.3.0.1.0,    root, default, AuditDaemon,    -106, error, 3955, "Error from device Code: 502 - Robot can not find target", Data=<response sequence="4288210" final="true"><command>audit</command><result identifier="1"><resultStatus><resultSeverity>error</resultSeverity><resultCode>5416</resultCode><resultText><!|CDATA|cmo_user_calibrate_column: Failed target calibration for (LRCSR) 1,3,-2,1,1, result code=5416; cmo_calibrate failed to find target for address (LRCSR) 1,3,-2,1,1 after 4 attempts, cmo_status=3; End of Text||></resultText><operationalState>502</operationalState></resultStatus><addressStatus>empty</addressStatus><address>1,3,-2,1,1</address><trackPosMils>254345</trackPosMils><label><!|CDATA|||></label></result></response>
2014-09-01T14:40:23.642,   1.0.0.0.0,    root, default, AuditDaemon,    -106, error, 3324, "Audit cannot complete due to hardware failure com.stortek.ats.elib.server.common.LcException: Robot operation failed Code: 502 - Robot can not find target", startAddress=1,3,-2,1,1 endAddress=1,3,-2,1,1

Changes

 After removing a stuck tape from a tape drive.

Cause

 Tape drive had missing target bezel on the front.

Solution

Installed missing bezel onto the tape drive.
 

References

<NOTE:1016199.1> - SL8500 - Failed Target Calibration - Result Code 5416
<NOTE:1527946.1> - SL8500 - 3324: "Audit Cannot Complete Due To Hardware Failure Com.stortek.ats.elib.server.common.LcException
<NOTE:1597333.1> - SL8500 - CMO_Calibrate Failed to Find Target for Address (LRCSR) 1,4,-54,x,x, Result Code 5501