SYSCHECK DISK 

Example: 
Running modules in class disk...
*       smart: FAILURE:: MINOR::5000000000000800 -- Server Disk Self Test Warning
*       smart: FAILURE::  Failure type: FailedReadSmartSelfTestLog, Failure message: Device: /dev/cciss/c0d0 [cciss_disk_11], Read SMART Self-Test Log Failed. Physical disk: 1I:1:12, Controller Slot: 3, Serial number: PPHWT8VB., First occurred: Fri Sep 28 08:53:53 2012 EDT.
*       smart: FAILURE:: MINOR::5000000000000800 -- Server Disk Self Test Warning
*       smart: FAILURE::  Failure type: FailedReadSmartData, Failure message: Device: /dev/cciss/c0d0 [cciss_disk_11], failed to read SMART values. Physical disk: 1I:1:12,

In this Document
Symptoms
Cause
Solution
 Identify faulty disk
 Procedure


Created from <SR 3-9345934781>

Applies to:

BNS Platform Hardware - Version DSR 3.0 and later
Tekelec

Symptoms

syscheck output example:

Running modules in class disk...
*       smart: FAILURE:: MINOR::5000000000000800 -- Server Disk Self Test Warning
*       smart: FAILURE::  Failure type: FailedReadSmartSelfTestLog, Failure message: Device: /dev/cciss/c0d0 [cciss_disk_11], Read SMART Self-Test Log Failed. Physical disk: 1I:1:12, Controller Slot: 3, Serial number: PPHWT8VB., First occurred: Fri Sep 28 08:53:53 012 EDT.
*       smart: FAILURE:: MINOR::5000000000000800 -- Server Disk Self Test Warning
*       smart: FAILURE::  Failure type: FailedReadSmartData, Failure message: Device: /dev/cciss/c0d0 [cciss_disk_11], failed to read SMART values. Physical disk: 1I:1:12, Controller

Cause

Disk drive failure.

Solution

Replace failed disk drive in D2200sb storage array.

Identify faulty disk

Execute SYSCHECK to identify faulty disk:

Running modules in class disk...
* smart: FAILURE:: MINOR::5000000000000800 -- Server Disk Self Test Warning
* smart: FAILURE:: Failure type: FailedReadSmartSelfTestLog, Failure message: Device: /dev/cciss/c0d0 [cciss_disk_11], Read SMART Self-Test Log Failed. Physical disk: 1I:1:12, Controller Slot: 3, Serial number: PPHWT8VB., First occurred: Fri Sep 28 08:53:53 2012 EDT.
* smart: FAILURE:: MINOR::5000000000000800 -- Server Disk Self Test Warning
* smart: FAILURE:: Failure type: FailedReadSmartData, Failure message: Device: /dev/cciss/c0d0 [cciss_disk_11], failed to read SMART values. Physical disk: 1I:1:12, Controller Slot: 3, Serial number: PPHWT8VB., First occurred: Fri Sep 28 08:53:53 2012 EDT.
* hpdisk: FAILURE:: MINOR::5000000001000000 -- HP Disk is resyncing.
* hpdisk: FAILURE:: Failure message: logicaldrive 1 for controller in slot 3 is Recovering.
* hpdisk: FAILURE:: MINOR::5000000001000000 -- HP Disk is resyncing.

To determine if the faulty disk is on the blade server or the D220sb storage array:

hpacucli ctrl slot=0 pd all show status (note slot=0 points test to the disk controller on the blade server)

physicaldrive 1I:1:1 (port 1I:box 1:bay 1, 600 GB): OK
physicaldrive 1I:1:2 (port 1I:box 1:bay 2, 600 GB): OK

hpacucli ctrl slot=3 pd all show status (note slot=3 points test to the disk controller on the D2200sb storage array):

DIH Controller slot 15
physicaldrive 1I:1:1 (port 1I:box 1:bay 1, 600 GB): OK
physicaldrive 1I:1:2 (port 1I:box 1:bay 2, 600 GB): OK
DIH storage array slot 16
physicaldrive 1I:1:1 (port 1I:box 1:bay 1, 600 GB): OK
physicaldrive 1I:1:2 (port 1I:box 1:bay 2, 600 GB): OK
physicaldrive 1I:1:3 (port 1I:box 1:bay 3, 600 GB): OK
physicaldrive 1I:1:4 (port 1I:box 1:bay 4, 600 GB): OK
physicaldrive 1I:1:5 (port 1I:box 1:bay 5, 600 GB): OK
physicaldrive 1I:1:6 (port 1I:box 1:bay 6, 600 GB): OK
physicaldrive 1I:1:7 (port 1I:box 1:bay 7, 600 GB): OK
physicaldrive 1I:1:8 (port 1I:box 1:bay 8, 600 GB): OK
physicaldrive 1I:1:9 (port 1I:box 1:bay 9, 600 GB): OK
physicaldrive 1I:1:10 (port 1I:box 1:bay 10, 600 GB): OK
physicaldrive 1I:1:11 (port 1I:box 1:bay 11, 600 GB): OK
physicaldrive 1I:1:12 (port 1I:box 1:bay 12, 600 GB): Failed

Procedure

  1. Unpack the replacement drive unit from the shipping box, label the new drive to identify it is a new drive to avoid errors during the process of removal.
  2. Open the DIH D2200SB drive drawer. Press the red lever on the front center to extend the drawer handle, Extend the drawer to gain access to the drives.
    CAUTION: Thermal regulation is maintained only when the drive drawer is closed. The drive
    temperature alarm is triggered under the following conditions:
    • A slow beep and flash (1 every 5 seconds) indicate that the drive drawer is open. The drives are not fully protected by system air flow.
    • A fast beep and flash (2 per second)—To avoid drive damage or data loss and storage blade shutdown, close the drive drawer immediately.
    • When the drives reach critical temperatures, the system shuts down.
  3. DRIVE Location:
    The drive count from left to right, front to the back:
    • row 1 disk 1, 2, 3
    • row 2 disk 4, 5, 6
    • row 3 disk 7,8
    • row 4 disk 9, 10
    • row 5 disk 11,12
  4. Remove the target drive and insert new replacement drive. When inserted, the Power and Spin LEDs are dark but should turn on within 15 second. Two green LEDs are visible on the top of the drive unit. If this does not occur, make sure the drive is properly inserted.
  5. Close Sidecar to avoid overheating.
  6. Enter SYSCHECK DISK command on the DIH TVOE ssh login to ensure the SYNC process has successfully started. See output example below. Example:
    Running modules in class disk...
    * smart: FAILURE:: MINOR::5000000000000800 -- Server Disk Self Test Warning
    * smart: FAILURE:: Failure type: FailedReadSmartSelfTestLog, Failure message: Device: /dev/cciss/c0d0 [cciss_disk_11], Read SMART Self-Test Log Failed. Physical disk: 1I:1:12, Controller Slot: 3, Serial number: PPHWT8VB., First occurred: Fri Sep 28 08:53:53 2012 EDT.
    * smart: FAILURE:: MINOR::5000000000000800 -- Server Disk Self Test Warning
    * smart: FAILURE:: Failure type: FailedReadSmartData, Failure message: Device: /dev/cciss/c0d0 [cciss_disk_11], failed to read SMART values. Physical disk: 1I:1:12, Controller Slot: 3, Serial number: PPHWT8VB., First occurred: Fri Sep 28 08:53:53 2012 EDT.
    * hpdisk: FAILURE:: MINOR::5000000001000000 -- HP Disk is resyncing.
    * hpdisk: FAILURE:: Failure message: logicaldrive 1 for controller in slot 3 is Recovering.
    * hpdisk: FAILURE:: MINOR::5000000001000000 -- HP Disk is resyncing.
  7. To observer the status of the disk syncing. This syncing may take up to 40 minutes:
    hpacucli ctrl slot=3 pd (determined from the syscheck command, Physical disk: 1I:1:12)