![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1920627.1 : M10 XSCF Hangs With REBOOT: COUNTER ERROR (reason=0x00 Counter=4 Threshold=3)
More than 3 XSCF panics within Created from <SR 3-9113450031> Applies to:Fujitsu M10-4 - Version All Versions to All Versions [Release All Releases]Fujitsu M10-4S - Version All Versions to All Versions [Release All Releases] Fujitsu M10-1 - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. SymptomsXSCF console sessions hang, front operator panel and rear XSCF Check LEDs are Changes
CauseThis appears to be the message put out following some hardening of the fault-->panic-->reboot scheme used for unexpected XSCF faults and introduced in FW 2070. SolutionRecovery from this situation requires an AC power cycle of the entire M10-4 system prior to FW 2091. Starting with FW 2091, it may be possible to recover the XSCF with a pushbutton reset.
References<BUG:18876055> - M10 XSCF REBOOT: COUNTER ERROR<NOTE:1570216.1> - Fujitsu M10-1/M10-4/M10-4S: System Backup Memory Access Error on Power Supply Backplane Attachments This solution has no attachment |
||||||||||||
|