Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1920162.1
Update Date:2017-12-17
Keywords:

Solution Type  Problem Resolution Sure

Solution  1920162.1 :   Running VTS on a T3-2 Server Causes Fatal Error in the PCIe Fabric on Solaris 11.2 release  


Related Items
  • SPARC T3-2
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: T3
  •  




In this Document
Symptoms
Cause
Solution


Applies to:

SPARC T3-2 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

SPARC T3-2 server running Solaris 11.2 will panic when running ORACLE VTS

Cause

On a SPARC T3-2 server running Solaris 11.2, any attempt to run Oracle Validation Test Suite (Oracle VTS Version: 7.18.1)
can cause a fatal error in the PCIe fabric regardless of whether it is started through the runvts option
(/usr/sunvts/bin/runvts), a command in a terminal window (/usr/sunvts/bin/startsunvts -t), or the graphical
user interface (/usr/sunvts/bin/startsunvts -g).  

Solution

Downgrade to a prior version of VTS.

- Issue the following commands if the system/test/sunvts package is not installed:

# pkg change-facet facet.version-lock.consolidation/SunVTS/SunVTS-incorporation=false

# pkg update SunVTS-incorporation@0.5.11-0.175.1.0.0.14.0

# pkg install system/test/sunvts

- Issue the following commands if the system/test/sunvts package is installed:

# pkg change-facet facet.version-lock.consolidation/SunVTS/SunVTS-incorporation=false

# pkg update SunVTS-incorporation@0.5.11-0.175.1.0.0.14.0 sunvts@7.0.14-0.175.1.0.0.14.0