Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1919687.1
Update Date:2017-05-19
Keywords:

Solution Type  Problem Resolution Sure

Solution  1919687.1 :   SL150 - Library Reports LTO6 Drives Are Running Too Hot  


Related Items
  • HP LTO6 Tape Drive
  •  
  • StorageTek SL150 Modular Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL500 Library
  •  




In this Document
Symptoms
Cause
Solution


Applies to:

HP LTO6 Tape Drive - Version All Versions and later
StorageTek SL150 Modular Tape Library - Version All Versions and later
Information in this document applies to any platform.

The drive was replaced after customer checked the airflow is not blocked to the drive. Still having the same issue!
The customer rebooted the library and it cleared the issue.

Symptoms

SL150 keeps claiming LTO6 drive runs too hot.

LTO-6hh FC: Drive indicating Maximum/Minimum temperature of 255

Following is taken from the Service Bundle:

S.OdsDriveEnclosure.;
1.ComponentStatus=Unknown
1.DriveFan=false
1.FanStatus=Unknown
1.FanSpeed=10980 <-----No Problem here!
1.FanWarnThreshold=4500
1.FanErrorThreshold=3000

S.OdsDriveInfo.;
1.VendorID=""
1.HpProductID=""
1.RevisionLevel=""
1.SerialNumber=""
1.FirmwareVersion=""
1.InterfaceType=""
1.LTOGeneration=""
1.AutoLoad=false
1.AutoEject=true
1.AutoThread=true
1.PacketSequence=false
1.UpgradeProtect=false
1.CleanProtect=false
1.TransportType=255
1.TransportDomain=255
1.InterfaceTypeAci=FiberChannel
1.LTOGenerationAci=6
1.Library=0
1.Module=1
1.Row=1
1.Column=11
1.IPAddress="10.0.0.1"

S.OdsDriveStatus.;
1.Exists=true
1.Available=false
1.Position=1
1.ElementAddress=500
1.LibraryModeEnabled=true
1.NeedsCleaning=false
1.CleaningInProgress=false
1.CleanExpired=false
1.SpecificCleanCart=false
1.WriteProtected=false
1.DriveError=false
1.MediaError=false
1.State=Inoperative
1.CompressionEnabled=false
1.PreventMediaRemoval=false
1.CartridgeLoadState=Unknown
1.CartridgeReadyForAccess=false
1.CartridgeReadyToEject=false
1.CartridgePresentFlag=false
1.ReadyLoad=false
1.CartridgeType=0
1.Beacon=false
1.HealthState=Problems
1.HealthReasonCode=9023
1.HealthReason="Drive temperature sensor has reached the shutdown level"
1.RobotAvailable=false
1.PrevState=Empty
1.PartitionNum=0
1.Temperature=255
<----- Problem is here!
1.TempWarnThreshold=60
1.TempErrorThreshold=70
1.OverTemp=false
1.Encrypting=false

Cause

 There is a code bug in the HP LTO6 half height code that randomly causes the drive to report a very high temperature and thus the library will shut the drive down to prevent heat damage.

Solution

This issue is resolved in HP LTO6 Firmware.

LTO-6HH (FC) Oracle 2.25 18620796 HP 23DS 150685-02
LTO-6HH (SAS) Oracle 2.25 18620796 HP 33ES 150063-03

 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.