![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1919291.1 : Cluster Health Monitory process CHM (ORA.CRF) Will Not Be Online Solaris Zone
The Cluster Health Monitor collects OS statistics (system metrics) such as memory and swap space usage, processes, IO usage, and network related data. The Cluster Health Monitor collects information in real time and usually once a second. In this Document
Created from <SR 3-9393927241> Applies to:SPARC SuperCluster T4-4 - Version All Versions and laterInformation in this document applies to any platform. Symptomsora.crf is the Cluster Health Monitor resource name that ohasd manages. Issue “crsctl stat res –t –init” to check the current status of the Cluster Health Monitor. The resource ora.crf is offline will be offline as in in the ouptut
./crsctl stat res -t -init ------------------------------------------------------------------------------- ora.asm .. ..
crfmond.log shows below
014-08-08 14:34:16.376: [ default][1]devmap /etc/path_to_inst file missing. Please rebuild this file.
2014-08-08 14:34:16.376: [ default][1]devmap /etc/path_to_inst file missing. Please rebuild this file. 2014-08-08 14:34:16.376: [ default][1]devmap /etc/path_to_inst file missing. Please rebuild this file. >>>>>>>>>>>>>>>>> 2014-08-08 14:34:16.376: [ CRFMOND][1]OSD error: op="fill_iospec" loc="devmap read " other="" dep="0" 2014-08-08 14:34:16.476: [ CRFMOND][1]mond_init: scrfosmctx init failed 2014-08-08 14:34:16.477: [ CRFMOND][1]Failed to init sysmond, exiting... 2014-08-08 14:34:16.701: [ default][1]clsmond_main: started with thread id 1 2014-08-08 14:34:16.879: [ COMMCRS][3]clsc_connect: (1001b5250) no listener at (ADDRESS=(PROTOCOL=ipc)(KEY=bt1ssse5d1z3DBG_MOND)) CauseThe issue is due to <Bug 17443419> which is a Duplicate of <Bug 16429265>. Solution
NOTE:This issue is seen in the Exadata on Solaris and Supercluster environments References<BUG:18011828> - MERGE REQUEST ON TOP OF GRID INFRASTRUCTURE PSU 11.2.0.3.8 FOR BUGS 13604285<NOTE:1328466.1> - Cluster Health Monitor (CHM) FAQ <BUG:12871634> - CRFMOND.LOG GETTING ERROR EVERY 5 MINUTES Attachments This solution has no attachment |
||||||||||||||||||
|