![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1919135.1 : C2 - SCSI Medium Changer Not Detected on the OS Level
In this Document
Created from <SR 3-9493301421> Applies to:Sun Storage C2 Tape Autoloader - Version All Versions and laterInformation in this document applies to any platform. SymptomsAutoloader was replaced. After replacement, the Medium Changer was not showing up in the cfgadm -alv / Os level CauseBy Default C2 Autoloader Change Mode = Sequential. Change it to RANDOM. SolutionBy Default C2 Autoloader Change Mode = Sequential. Change it to RANDOM and Reboot the server. Another thing that can cause the issue is SCSI HBA not set to MLUN Support. Go go SCSI BIOS and only for the SCSI id that C2 Autoloader is assigned, change the setting Multiple LUN (MLUN) to yes / enable. Attachments This solution has no attachment |
||||||||||||||||
|