Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1917803.1
Update Date:2017-05-05
Keywords:

Solution Type  Problem Resolution Sure

Solution  1917803.1 :   SL150 - Library Will Not Initialize, FSC9141 and FSC9142  


Related Items
  • StorageTek SL150 Modular Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL150 Library
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-9475448529>

Applies to:

StorageTek SL150 Modular Tape Library - Version All Versions and later
Information in this document applies to any platform.

This is a new install of the SL150.
There are a total of 7 modules installed.

Symptoms

Library will not initialize.

9141 Robot Z Locate Sensor Always off Expansion Module 2

9142 Robot Z Locate Sensor Always on Expansion Module 2

   

Changes

New installation of library.

Cause

There was a defective sensor in the expansion module.

Solution

Replaced defective expansion module to resolve issue.

7021882 [C] Expansion Module Chassis

SL150 - How To Remove/Replace an Expansion Module Chassis CRU in the StorageTek SL150 Modular Tape Library:ATR:1473453.1:0 (Doc ID 1473453.1)

Note: There was a documentation issue in older FSC information.  This is being resolved in 2.50 firmware due out in Dec. 2014.  Refer to the following knowledge entry for further details.

SL150 - Incorrect Remedy or Suggested Action Information in User's Guide (Doc ID 1917764.1)

Note: The Z sensor is not the same as the magazine sensor.

References

<NOTE:1532413.1> - SL150 - Initialization Failure, Robot Z Home Sensor Initialization Error, Fault Code 9135

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.