![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1917705.1 : Cfgadm -al -o Show_SCSI_LUN : Configuration Administration Not Supported
In this Document
Created from <SR 3-9481212548> Applies to:Sun SPARC Enterprise M5000 Server - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. Symptoms# cfgadm -al -o show_SCSI_LUN ChangesReplaced faulty hba's and moved to different slots Causehba paths are different than what is actually in /dev/cfg c1 -> ../../devices/pci@3,700000/SUNW,qlc@0/fp@0,0:fc
c3 -> ../../devices/pci@13,700000/SUNW,qlc@0/fp@0,0:fc c4 -> ../../devices/pci@3,700000/SUNW,qlc@0,1/fp@0,0:fc c5 -> ../../devices/pci@13,700000/SUNW,qlc@0,1/fp@0,0:fc
# grep "OS Device" <explorer_dir>/sysconfig/fcinfo.out
OS Device Name: /devices/pci@0,600000/pci@0/pci@8/pci@0,1/SUNW,qlc@1/fp@0,0:fc OS Device Name: /devices/pci@0,600000/pci@0/pci@8/pci@0,1/SUNW,qlc@1,1/fp@0,0:fc OS Device Name: /devices/pci@10,600000/pci@0/pci@8/pci@0,1/SUNW,qlc@1/fp@0,0:fc OS Device Name: /devices/pci@10,600000/pci@0/pci@8/pci@0,1/SUNW,qlc@1,1/fp@0,0:fc SolutionRun Attachments This solution has no attachment |
||||||||||||||||||
|