![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1917365.1 : SL150 - Error Message / Module Count is Greater than Z Range for Modules Calculation: MCI ModCnt
In this Document
Created from <SR 3-9472614841> Applies to:StorageTek SL150 Modular Tape Library - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsDuring initialization the following series of errors are seen in the error logs and the library does not go online (goes inop). 2014-08-06T12:24:02.626, 0.0.0.0.0, 519, robot, /usr/local/bin/Ifm, error, 0000, 1228, "Director - initResponse() directorSelfInit; MCI Module Count is Greater than Z Range for Modules Calculation: MCI ModCnt=3, Z Sweep ModCnt=2; End of Text" 2014-08-06T12:24:02.646, 0.0.0.0.0, 3202, ifm, error, 0100, 1228, "IfmInitThread:Failure to Initialize...reason==The number of KLEs seen by MCI does not match Z's range for Modules - GOING INOP" 2014-08-06T12:24:03.627, 0.0.0.0.0, 3750, processMgr, error, 3750, 3755, "Process /usr/local/share/sbin/snmptrapd murdered by signal 11"
ChangesCustomer install a new Expansion Module. CauseThe new Expansion Module has problems with his Expansion Module Controller (KLE) Card. You will see wrong Drive IDs. 2014-08-06T12:24:24.670, 0.0.0.0.0, 000, VMonitor, , error, 0000, 7027, "VMonitorDriveInit driveInfo::issueCommand(): Drive Get Info Response Bad Result Code = 6414 For Drive ID 3" SolutionReplace the Expansion Module Controller (KLE) Card.
Attachments This solution has no attachment |
||||||||||||||||||||
|