![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1917077.1 : Sun Storage 2500 Array: Firmware Upgrade Reports "Storage partitions database corruption"
In this Document
Created from <SR 3-7069151753> Applies to:Sun Storage 2540 Array - Version Not Applicable and laterSun Storage 2510 Array - Version Not Applicable and later Sun Storage 2530 Array - Version Not Applicable and later Information in this document applies to any platform. SymptomsWhen attempting to upgrade controller firmware on a Sun Storage 2500 Array from 06.x to 07.x using the Sun Storagetek 25xx Series Firmware Upgrade Utility, the verification process reports the following:
Storage partitions database corruption: There is a storage partitions mapping database error on controller X. You cannot upgrade the storage array until the problem is resolved. Contact your technical support representative to resolve this issue.
CauseThe upgrade utility has identified a condition that might prevent the upgrade from completing successfully. SolutionTo clear this condition, reset each controller before running the upgrade utility. This step is described in the "Sun StorageTek 2500 Series Array Firmware Upgrade Guide" under chapter "Resetting Each Controller Using CAM" page 7. References<BUG:15513748> - SUNBT6757069 UNABLE TO UPGRADE LCA ARRAYS FROM DESPERADO FIRMWARE TO EXMOOR FIRMAttachments This solution has no attachment |
||||||||||||||||||
|