![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1916946.1 : Fujitsu M10-1/M10-4/M10-4S; Hot-replacement of FANs/PSUs on M10 PCI Expansion Unit Cannot be Performed
In this Document
Applies to:Fujitsu M10-4 - Version All Versions and laterFujitsu M10-4S - Version All Versions and later Fujitsu M10-1 - Version All Versions and later Fujitsu M10 PCI Expansion Unit - Version All Versions and later Oracle Solaris on SPARC (64-bit) SymptomsAfter an XSCF reset or an XCP flashupdate the PCI Epansion Unit will no longer be accessible by the ioxadm or replacefru commands. The showhardconf and showstatus commands will not display the correct information Example 1: XSCF> ioxadm list Example 2: XSCF> showstatus Because the PCI-BOX identifier is missing clearstatus will also not work. Changes
CauseIssue is caused by a bug in XCP2090, 2091, 2092, 2210. An XSCF reset will occur when the following commands are executed flashupdate, setdate, rebootxscf, switchscf, or during a process down / watchdog timeout recovery. SolutionThis issue is fixed in XCP versions newer than 2210 Please apply the latest XCP release. See doc 1554086.1
How to replace a PSU or FAN on the PCI Expansion Box if the XCP can not be immediately updated: On the M10-1
On the M10-4/4S
How to recover when this problem happens: On the M10-1
On the M10-4/4S
See also Fujitsu Emergency Notice EN0009-TB45021_03 References<NOTE:1554086.1> - Fujitsu M10-1/M10-4/M10-4S XSCF Control Package (XCP) Firmware Image Software Version Matrix InformationAttachments This solution has no attachment |
||||||||||||||||||||
|