Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1916769.1
Update Date:2014-11-17
Keywords:

Solution Type  Problem Resolution Sure

Solution  1916769.1 :   ASM Griddisk, Diskgroup and Failure Group Mapping Is Not as Recommended  


Related Items
  • Exadata Database Machine X2-2 Full Rack
  •  
Related Categories
  • PLA-Support>Eng Systems>Exadata/ODA/SSC>Oracle Exadata>DB: Exadata_EST
  •  
  • _Old GCS Categories>ST>Server>Engineered Systems>Exadata>Troubleshooting and Debugging
  •  




Created from <SR 3-9293907041>

Applies to:

Exadata Database Machine X2-2 Full Rack - Version All Versions and later
Linux x86-64

Symptoms

When running automatic checks:

Grid Disk name RECOC2_CD_09_rmpf_celadm10 does not have cell name () suffix Naming convention not used. Cannot proceed further with  automating checks and repair for bug 12433293.

The hostname of storage cells is RFC 1123 compliant however the restrictions to the values of attributes do not allow the use of the hyphen "-" symbol.

CellCLI Object Attributes Using the CellCLI Utility 8-9
Restrictions on Values of Common Attributes
The following restrictions apply to the values of attributes common to multiple CellCLI objects.
The value of the name attribute must be less than 256 characters and composed only of the following ASCII characters (alphanumeric and underscore only):
        Lowercase alphabetic characters (a to z)
        Uppercase alphabetic characters (A to Z)
        Numbers (0 to 9)
        Underscore (_)

root@rmpf-dbadm01 onecommand]# dcli -g cell_group cellcli -e list cell
rmpf-celadm01: rmpf_celadm01     online
rmpf-celadm02: rmpf_celadm02     online
rmpf-celadm03: rmpf_celadm03     online
rmpf-celadm04: rmpf_celadm04     online
rmpf-celadm05: rmpf_celadm05     online
rmpf-celadm06: rmpf_celadm06     online
rmpf-celadm07: rmpf_celadm07     online
rmpf-celadm08: rmpf_celadm08     online
rmpf-celadm09: rmpf_celadm09     online
rmpf-celadm10: rmpf_celadm10     online
rmpf-celadm11: rmpf_celadm11     online
rmpf-celadm12: rmpf_celadm12     online
rmpf-celadm13: rmpf_celadm13     online
rmpf-celadm14: rmpf_celadm14     online
[root@rmpf-dbadm01 onecommand]# dcli -g cell_group cellcli -e list griddisk
rmpf-celadm01: DATAC1_CD_00_rmpf_celadm01        active
rmpf-celadm01: DATAC1_CD_01_rmpf_celadm01        active
rmpf-celadm01: DATAC1_CD_02_rmpf_celadm01        active
rmpf-celadm01: DATAC1_CD_03_rmpf_celadm01        active
rmpf-celadm01: DATAC1_CD_04_rmpf_celadm01        active
rmpf-celadm01: DATAC1_CD_05_rmpf_celadm01        active

Cause

Bug 18687078 ASM GRIDDISK,DISKGROUP AND FAILURE GROUP MAPPING IS NOT AS RECOMMENDED

From the bug.

Done the changes to handle special character.

Fixed will be available in 2.2.5 (exachk)


Solution

Automatic checks based on Exachk 2.2.5 and later will show properly
For automatic checks based on earlier versions of Exachk, you can ignore this.