Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1916632.1
Update Date:2014-10-16
Keywords:

Solution Type  Problem Resolution Sure

Solution  1916632.1 :   SuperCluster - Select Statement Returns Wrong Results with replace  


Related Items
  • Oracle SuperCluster M6-32 Hardware
  •  
  • Oracle SuperCluster T5-8 Hardware
  •  
  • Oracle SuperCluster T5-8 Half Rack
  •  
  • Oracle Database - Enterprise Edition
  •  
  • SPARC SuperCluster T4-4
  •  
  • Oracle SuperCluster T5-8 Full Rack
  •  
Related Categories
  • PLA-Support>Eng Systems>Exadata/ODA/SSC>SPARC SuperCluster>DB: SuperCluster_EST
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-9364838941>

Applies to:

Oracle Database - Enterprise Edition - Version 11.2.0.4 to 12.1.0.1 [Release 11.2 to 12.1]
Oracle SuperCluster M6-32 Hardware - Version All Versions to All Versions [Release All Releases]
SPARC SuperCluster T4-4 - Version All Versions to All Versions [Release All Releases]
Oracle SuperCluster T5-8 Hardware - Version All Versions to All Versions [Release All Releases]
Oracle SuperCluster T5-8 Full Rack - Version All Versions to All Versions [Release All Releases]
Oracle Solaris on SPARC (64-bit)

Symptoms

Simple select predicates returning wrong results when the query is run on SuperCluster.Correct results are  returned  if cell_offload_processing is set to false. Known to affect queries containing "REPLACE" function.

 

Cause

The problem  could be due to the following bug:

 Bug 19296555 - SUPERCLUSTER: SELECT RETURNS WRONG RESULT

Solution

 Apply a fix for Bug 19296555 - SUPERCLUSTER: SELECT RETURNS WRONG RESULT

or

Set cell_offload_processing is set to false  ( as a temporary workaround)

References

<BUG:19420986> - BLR BACKPORT OF BUG 19296555 ON TOP OF 11.2.0.4.0 (BLR #3980643)
<BUG:19296555> - QUERY WITH SIMPLE SELECT PREDICATES RETURNS WRONG RESULTS IN SSC

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback