![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1915971.1 : SL150 - Base Module Drives Not Recognized from Media Servers after Library Reboot
In this Document
Created from <SR 3-9376489731> Applies to:StorageTek SL150 Modular Tape Library - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. Customer Platform: SL150 Library(FW 2.25) 4EA HP LTO6 FC Drives(FW upgraded from 22GS to 23DS) Media Server: AIX 7.1, Windows 2008 Brocade Switch: Fabric OS 6.31a SymptomsACTUAL BEHAVIOR ChangesNew installation of SL150. Cause Brocade FW(Fabric OS) issue(Doc ID 1533738.1). Need to upgrade SAN Switch version to recommended version 6.4.2a, 7.0.0a and 6.3.2c. SolutionUpgrade SAN Switch FW(Fabric OS) to 6.4.2a, 7.0.0a and 6.3.2c or above version. References<NOTE:1495340.1> - SL150 - BackUp Software Application Does Not Detect or Use Both the Library and Drive<NOTE:1533738.1> - SL150 - Fibre Channel Library Can Not Be Recognized by Server After Reboot Attachments This solution has no attachment |
||||||||||||||||||||
|