![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1915566.1 : SL3000 - Library Totally Hung After Opening AEM Doors Before "Enter Light Came On"
In this Document
Created from <SR 3-9452167625> Applies to:Sun StorageTek SL3000 Modular Library System - Version All Versions and laterInformation in this document applies to any platform. SymptomsSun StorageTek SL3000 Modular Library System: completely down, hung status. Log entries: 2014-08-07T13:54:16.083, 1.1.31.2.0, root, default, internal, 0, error, 3204, "System error - Invalid state transition", state=Not Ready transtion=Physical audit
2014-08-07T13:54:17.317, 1.0.0.0.0, root, default, internal, 0, warn, 3881, "Library door opened", device=left 2014-08-07T13:55:06.386, 1.0.0.0.0, root, default, internal, 0, warn, 3882, "Library door closed", device=left 2014-08-07T13:57:24.970, 1.1.0.2.0, root, default,RobotInitial, -102, error, 3955, "Error from device Code: 508 - Robot says location is unusable", Data=<response sequence="531356" final="true"><command>moveToPosition</command><result identifier="1"><resultStatus><resultSeverity>error</resultSeverity><resultCode>5634</resultCode><resultText><!|CDATA|End of Text||></resultText><operationalState>508</operationalState></resultStatus><address>1,1,33,2,0</address><trackPosMils>0</trackPosMils></result></response> 2014-08-07T13:57:24.986, 1.1.0.2.0, root, default,RobotInitial, -102, error, 1319, "Robot operation failed Code: 508 - Robot says location is unusable", Data:=<response sequence="531356" final="true"><command>moveToPosition</command><result identifier="1"><resultStatus><resultSeverity>error</resultSeverity><resultCode>5634</resultCode><resultText><!|CDATA|End of Text||></resultText><operationalState>508</operationalState></resultStatus><address>1,1,33,2,0</address><trackPosMils>0</trackPosMils></result></response> 2014-08-07T13:57:24.989, 1.0.0.0.0, root, default,RobotInitial, -102, error, 3215, "Robot initialization error - Data: 2014-08-07T13:57:24.986, 1.1.0.2.0, root, default, internal, 0, error, 1319, "Robot operation failed Code: 508 - Robot says location is unusable", Data:=<response sequence="531356" final="true"><command>moveToPosition</command><result identifier="1"><resultStatus><resultSeverity>error</resultSeverity><resultCode>5634</resultCode><resultText><!|CDATA|End of Text||></resultText><operationalState>508</operationalState></resultStatus><address>1,1,33,2,0</address><trackPosMils>0</trackPosMils></result></response>"
ChangesCustomer opened AEM doors before "enter light came on" CauseAccording to the logs confirmed what the FE found onsite the library went into a hung status when customer entered into the library. Customer opened AEM doors before "enter light came on".
SolutionReboot the library and check functionality. Attachments This solution has no attachment |
||||||||||||||||||
|