Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1915566.1
Update Date:2017-09-26
Keywords:

Solution Type  Problem Resolution Sure

Solution  1915566.1 :   SL3000 - Library Totally Hung After Opening AEM Doors Before "Enter Light Came On"  


Related Items
  • Sun StorageTek SL3000 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-9452167625>

Applies to:

Sun StorageTek SL3000 Modular Library System - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Sun StorageTek SL3000 Modular Library System: completely down, hung status.

Log entries:

 2014-08-07T13:54:16.083,  1.1.31.2.0,    root, default,    internal,       0, error, 3204, "System error - Invalid state transition", state=Not Ready transtion=Physical audit  


 2014-08-07T13:54:16.783, 1.1.-31.2.0,    root, default,    internal,       0, error, 3204, "System error - Invalid state transition", state=Not Ready transtion=Physical audit  

2014-08-07T13:54:17.317,   1.0.0.0.0,    root, default,    internal,       0,  warn, 3881, "Library door opened", device=left  

2014-08-07T13:55:06.386,   1.0.0.0.0,    root, default,    internal,       0,  warn, 3882, "Library door closed", device=left  

2014-08-07T13:57:24.970,   1.1.0.2.0,    root, default,RobotInitial,    -102, error, 3955, "Error from device Code: 508 - Robot says location is unusable", Data=<response sequence="531356" final="true"><command>moveToPosition</command><result identifier="1"><resultStatus><resultSeverity>error</resultSeverity><resultCode>5634</resultCode><resultText><!|CDATA|End of Text||></resultText><operationalState>508</operationalState></resultStatus><address>1,1,33,2,0</address><trackPosMils>0</trackPosMils></result></response>  

2014-08-07T13:57:24.986,   1.1.0.2.0,    root, default,RobotInitial,    -102, error, 1319, "Robot operation failed Code: 508 - Robot says location is unusable", Data:=<response sequence="531356" final="true"><command>moveToPosition</command><result identifier="1"><resultStatus><resultSeverity>error</resultSeverity><resultCode>5634</resultCode><resultText><!|CDATA|End of Text||></resultText><operationalState>508</operationalState></resultStatus><address>1,1,33,2,0</address><trackPosMils>0</trackPosMils></result></response>  

2014-08-07T13:57:24.989,   1.0.0.0.0,    root, default,RobotInitial,    -102, error, 3215, "Robot initialization error - Data: 2014-08-07T13:57:24.986,   1.1.0.2.0,    root, default,    internal,       0, error, 1319, "Robot operation failed Code: 508 - Robot says location is unusable", Data:=<response sequence="531356" final="true"><command>moveToPosition</command><result identifier="1"><resultStatus><resultSeverity>error</resultSeverity><resultCode>5634</resultCode><resultText><!|CDATA|End of Text||></resultText><operationalState>508</operationalState></resultStatus><address>1,1,33,2,0</address><trackPosMils>0</trackPosMils></result></response>"  

 

Changes

 Customer opened AEM doors before "enter light came on"

Cause

According to the logs confirmed what the FE found onsite the library went into a hung status when customer entered into the library. Customer opened AEM doors  before "enter light came on".
 
When they opened the AEM doors and entered before the library provided authorization, then generated a hung issue as the library must protect the humans for any injuries. Customer must wait until the library is prepared to allow a human entered after the AEM door is opened.

 

Solution

Reboot the library and check functionality.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback