Solution Type  Problem Resolution Sure

Solution  1914420.1 :   ODA : Fixing the wrong network connection media option when reimaging the X4-2 : How to switch between the Connection types Fiber or Copper twisted-pair during VM reimaging on X4-2  


Related Items
  • Oracle Database Appliance X4-2
  •  
Related Categories
  • PLA-Support>Eng Systems>Exadata/ODA/SSC>Oracle Database Appliance>DB: ODA_EST
  •  
  • Tools>Primary Use>Configuration
  •  




Applies to:

Oracle Database Appliance X4-2 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

ODA on X4-2

THESE STEPS CAN ONLY BE USED AFTER A REDEPLOYMENT

 

oakcli show env_hw

 add outputs showing how to confirm the connection types currently in use exist within the script which can be found

Changes

Using X4-2

  • Performing a re-image, bare metal restore or clean installation using ISO images to build the ODA from the OS up.
     
  • Bare Metal to Virtualized ODA configuration
  • Virtualized to Bare Metal ODA configuration
  • Requiring changes in the port connection type after an installation

  

 

Cause

Usually this happens when accidentally choosing the wrong connection type when prompted during the installation or reimage process

A reimage is common after

Switching between

  • Bare Metal and Virtualization Installations
  • If changing ASM disk redundancy
  • If changing ASM disk Storage between Local and External
  • Rapid deployment to the newest ODA version in order to skip upgrade steps
  • Wanting to create a Clean machine installation due to administrative choices

 

Solution

Running  the script setupX4Network.pl on the X4-2 will allow you to change the network connection by choosing between a Fiber or Twisted-Pair / Copper Connection type:

If you make a mistake or need to change your public network choice later, reconfigure your system by running the script /opt/oracle/oak/lib/setupX4network.pl as the root user on both nodes.

Note: the ODA will auto-detect if the connection is 10gbe or 1 gbe regardless of the media type chosen.

  

STEPS

Run the following      

/opt/oracle/oak/lib/setupX4Network.pl


After the script performs several internal checks you will be prompted for the following:

"Do you want to use Fiber or Copper cards for public network? Please Choose [C]opper or [F]iber."

 

Then your will see either of the following confirmations based on your choice

 

"User has chosen to configure Fiber cards for public network"

- or -

"User has chosen to configure Copper cards for public network"

 
 