Created from <SR 3-9337802121>
Applies to:
Sun StorageTek SL500 Modular Library System - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
Symptoms
On : Environment
Product Type: Sun StorageTek SL500 Modular Library System
Platform: All Platforms
Platform Ver: N/A
ACTUAL BEHAVIOR
---------------
After changing the hostname for the library the details are not captured in SNMP.
EXPECTED BEHAVIOR
-----------------------
When changing the hostname of the library, it should also be captured in SNMP.
Cause
Customer tried to change SNMP from their application server but the old name still appears.
Customer did not know how to copy the entire MIB template.
Solution
Copying the MIB Text File:
The MIB text resides within the library controller card. Users must copy this file using the Transfer File utility available with version 2.91 (2.26.00) or higher of StorageTek Library Console.
To c o p y t h e M I B f i l e :
1. Log on to the library using StorageTek Library Console.
2. Choose Tools ⇒ Diagnostics.
3. Choose the TransferFile tab.
4. Click the Transfer button next to the STREAMLINE_TAPE_LIBRARY_MIB_TEXT.text file.
5. In the Save dialog box, choose a Save in folder.
6. Type in a file name.
7. Click Save.
Attachments
This solution has no attachment