Solution Type Problem Resolution Sure Solution 1911686.1 : HP LTO6 - Can Not Access Drive Through ACSLS
In this Document
Created from <SR 3-9384487251> Applies to:Sun StorageTek Auto Cartridge Sys Lib SW (ACSLS) - Version 8.0 and laterHP LTO6 Tape Drive - Version All Versions and later Information in this document applies to any platform. New install and drive comes up as invalid. Current level of ACSLS is 8.0.1. SymptomsHP LTO6 Tape Drive cannot be accessed through ACSLS. ChangesNew Installation. CauseInstalled version of ACSLS does not support LTO6 drives. SolutionCustomer needs to install ACSLS 8.2 or higher. Attachments This solution has no attachment |
||||||||||||||||||||
|