Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1910148.1
Update Date:2016-08-14
Keywords:

Solution Type  Problem Resolution Sure

Solution  1910148.1 :   Oracle ZFS Storage Appliance: Clone operation failed - SMB resource name already in use.  


Related Items
  • Sun ZFS Storage 7420
  •  
  • Oracle ZFS Storage ZS3-2
  •  
  • Sun Storage 7110 Unified Storage System
  •  
  • Oracle ZFS Storage ZS4-4
  •  
  • Sun Storage 7210 Unified Storage System
  •  
  • Sun Storage 7410 Unified Storage System
  •  
  • Sun ZFS Storage 7120
  •  
  • Oracle ZFS Storage ZS3-4
  •  
  • Sun Storage 7310 Unified Storage System
  •  
  • Oracle ZFS Storage Appliance Racked System ZS4-4
  •  
  • Sun ZFS Storage 7320
  •  
  • Oracle ZFS Storage ZS3-BA
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: 7xxx NAS
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-9210113641>

Applies to:

Sun Storage 7410 Unified Storage System - Version All Versions and later
Sun Storage 7310 Unified Storage System - Version All Versions and later
Sun Storage 7210 Unified Storage System - Version All Versions and later
Sun Storage 7110 Unified Storage System - Version All Versions and later
Sun ZFS Storage 7420 - Version All Versions and later
7000 Appliance OS (Fishworks)

Symptoms

The clone operation failed because one or more of the shares' SMB resource names is already in use.

Check that the replicated project and its shares are not currently shared via SMB.

 

Cause

It is caused by the resource name on the replicated SMB share being set to 'on'

 

Resource name:  The name by which SMB clients refer to this share.

The resource name "off" indicates no SMB client may access the share, and the resource name "on" indicates the share will be exported with the filesystem's name.

 

Solution

Change the resource name on the replicated SMB share from 'on' to 'off'.

The clone operation will then succeed on the replicated share in target head.

 

 

References

<BUG:15615612> - SUNBT6917160 NAS REPLICATION: CAN'T CLONE PROJECT SHARED VIA CIFS

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback