Solution Type  Problem Resolution Sure

Solution  1909172.1 :   SL3000 - SNMP Settings Are Not Working  


Related Items
  • Sun StorageTek SL3000 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  


SL3000 unable to implement a new tool which uses SNMP traps.

In this Document
Symptoms
Cause
Solution


Created from <SR 3-9251753551>

Applies to:

Sun StorageTek SL3000 Modular Library System - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Symptoms

SNMP settings not working.

Problem Description
---------------------------------------------------
We are trying to change SNMP settings, and are getting syntax errors. 

Cause

 Library is running an old FW version (3.00).

Solution

 It is highly recommended to upgrade Firmware version of the library to 3.60 or higher.