![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1907439.1 : Sun Storage Common Array Manager (CAM): CAM reports alarm of "Tray.xx.Controller.x is at revision "xx.xx.xx.xx" baseline version is "xx.xx.xx.xx""
In this Document
Applies to:Sun Storage 2530-M2 Array - Version Not Applicable and laterSun Storage 6540 Array - Version All Versions and later Sun Storage 6180 Array - Version All Versions and later Sun Storage 2540 Array - Version Not Applicable and later Sun Storage 2530 Array - Version Not Applicable and later Information in this document applies to any platform. SymptomsSun Storage Common Array Manager (CAM) reports the following alarm with event code xx.75.42: Scenario 1 (baseline version is higher than controller firmware): Alarm Details (xx)
Severity: Major Date: xxxxxx State: Open Acknowledged By: Auto Clear Yes Description: Tray.xx.Controller.A is at revision "07.80.xx.xx" baseline version is "07.84.xx.xx" Tray.xx.Controller.B is at revision "07.80.xx.xx" baseline version is "07.84.xx.xx" Info: Device: xxxxx Component: xxxxx Event Code: xx.75.42 Aggregated Count: 0 Scenario 2 (baseline version is lower than controller firmware): Alarm Details (xx)
Severity: Major Date: xxxxx State: Open Acknowledged By: Auto Clear Yes Description: Tray.xx.Controller.A is at revision "07.84.xx.xx" baseline version is "07.80.xx.xx" Tray.xx.Controller.B is at revision "07.84.xx.xx" baseline version is "07.80.xx.xx" Info: Device: xxxxx Component: xxxxx Event Code: xx.75.42 Aggregated Count: 0 CauseEach CAM version comes bundled with specific versions of array controller firmware for Sun Storage Arrays. These are called CAM baseline firmware. The alarm with event code xx.75.42 indicates a mismatch between CAM baseline firmware and the current array controller firmware. Scenario 1 indicates that the CAM baseline version is higher than the controller firmware running on the array. This usually happens when CAM software is upgraded, but the controller firmware is not upgraded yet. Scenario 2 indicates that the CAM baseline version is lower than the controller firmware running on the array. This usually happens if a new array is registered in an existing CAM instance. CAUTION: For Scenario 2, do not click "Install baseline firmware". This may downgrade array firmware to an older version, the array's data and configuration may be lost.
Similar alarms occur for array disk drives as well, as described in <Document 1338039.1> Sun Storage Common Array Manager reports the alarm "Tray.xx.Drive.yy is at revision "B" baseline version is "A". Solution
To resolve this alarm: For Scenario 1: Upgrade the controller firmware to match the baseline firmware.
In case of online firmware upgrade with Solaris data servers attached to the array, ensure the settings as recommended in <Document 1569976.1> Recommended Setting for the "fcp_offline_delay" Variable When Upgrading a Sun Storage 6000, 2500 or 2500-M2 Controller Firmware before you proceed with an online upgrade.
For Scenario 2: Upgrade CAM. To identify the current version of CAM, refer to <Document 1011180.1> How to Determine the Version of Sun Storage Common Array Manager (CAM). Download and install the latest CAM revision, refer to <Document 1296274.1> How to Download Common Array Manager (CAM) Software and Patches. With the latest version of CAM, if it leads to Scenario 1, upgrade the controller firmware to match the baseline firmware.
Do you still have questions? You can use My Oracle Support Communities. Communities put you in touch with industry professionals like yourself. They are monitored by Oracle support engineers, so you can expect reliable and correct answers. Ask questions and see what others are asking about in the Disk Storage 2000, 3000, 6000 RAID Arrays & JBODs Community.
References<NOTE:1338039.1> - Sun Storage Common Array Manager reports the alarm "Tray.xx.Drive.yy is at revision "B" baseline version is "A""<NOTE:1319254.1> - Procedure to Upgrade the Sun StorageTek[TM] 2500 Series Array Controller Firmware from 06.xx to 07.xx. <NOTE:1131593.1> - Procedure to Upgrade the Sun StorageTek[TM] 6540 Array, 6140 Array or FLX380 Storage Array from Firmware 06.xx to 07.xx. <NOTE:1569976.1> - Recommended Setting for the "fcp_offline_delay" Variable When Upgrading a Sun Storage 6000, 2500 or 2500-M2 Controller Firmware <NOTE:1296274.1> - How to Download Common Array Manager (CAM) Software and Patches <NOTE:1576648.1> - How to Recover a Sun Storage 2500-M2 Array After a Firmware Downgrade from 07.84.xx.xx to 07.80.xx.xx Attachments This solution has no attachment |
||||||||||||||||||
|