Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1905203.1
Update Date:2017-10-05
Keywords:

Solution Type  Problem Resolution Sure

Solution  1905203.1 :   FRUID contents are corrupt message yet components are seen correctly by ILOM  


Related Items
  • SPARC T4-1
  •  
  • SPARC T4-4
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: T4
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-9290756391>

Applies to:

SPARC T4-1 - Version All Versions to All Versions [Release All Releases]
SPARC T4-4
Information in this document applies to any platform.

Symptoms

In this instance the customer got the following in show faulty.

 

-> show faulty
Target | Property | Value
---------------------------------------+----------------------------------------------+-------------------------------------------------------------------
/SP/faultmgmt/0 | fru | /SYS/MB/RISER2
/SP/faultmgmt/0/faults/0 | class | fault.fruid.corrupt
/SP/faultmgmt/0/faults/0 | sunw-msg-id | ILOM-8000-2V
/SP/faultmgmt/0/faults/0 | component | /SYS/MB/RISER2
/SP/faultmgmt/1 | fru | /SYS/PDB
/SP/faultmgmt/1/faults/0 | class | fault.fruid.corrupt
/SP/faultmgmt/1/faults/0 | sunw-msg-id | ILOM-8000-2V
/SP/faultmgmt/1/faults/0 | component | /SYS/PDB
/SP/faultmgmt/2 | fru | /SYS/SASBP
/SP/faultmgmt/2/faults/0 | class | fault.fruid.corrupt
/SP/faultmgmt/2/faults/0 | sunw-msg-id | ILOM-8000-2V
/SP/faultmgmt/2/faults/0 | component | /SYS/SASBP

 

However when we looked at the actual FRUs we can see the components just fine.


(From Snapshot)

FRU Device Description : DBP (LUN 0, ID 210) <strong>&lt;------------------------------------- Same as /SYS/SASBP</strong>
 Board Mfg             : 9615 HON HAI PRECISION CO. LTD SHENZHEN GUANGDONG CN
 Board Product         : BD,SATA,LOUISE,8DSK_BKPLN
 Board Serial          : 0226LHF-12120N0EHY
 Board Part Number     : 511-1435-02
 Board Extra           : Rev 05

FRU Device Description : PDB (LUN 0, ID 211)
 Board Mfg             : 9615 HON HAI PRECISION CO. LTD SHENZHEN GUANGDONG CN
 Board Product         : BD,LOUISE,HPDB
 Board Serial          : 0226LHF-1210F601EE
 Board Part Number     : 541-4223-03
 Board Extra           : Rev 51
FRU Device Description : MB/RISER2 (LUN 0, ID 224)
 Board Mfg             : 5030 CELESTICA CORP. SRIRACHA CHONBURI TH
 Board Product         : BD,NON-XAUI RISER
 Board Serial          : 1005LCB-1222B90YNL
 Board Part Number     : 541-4085-04
 Board Extra           : Rev 50

 

Cause

 This is most likely a temporary communication loss between the SP and the system

Solution

 Clear the faults and reset the SP

  • start /SP/faultmgmt/shell
  • fmadm repaired <component> (for each component affected)
  • exit
  • reset /SP

 

References

<BUG:18356258> - SPARC T5-2: MULTIPLE COMPONENTS REPORTS CORRUPTED FRUID SY
<NOTE:1168559.1> - ILOM-8000-2V - FRUID contents are corrupt
<NOTE:1331308.1> - SPARC T3-2 Current Product Issues

Attachments