![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1905203.1 : FRUID contents are corrupt message yet components are seen correctly by ILOM
In this Document
Created from <SR 3-9290756391> Applies to:SPARC T4-1 - Version All Versions to All Versions [Release All Releases]SPARC T4-4 Information in this document applies to any platform. SymptomsIn this instance the customer got the following in show faulty.
-> show faulty
However when we looked at the actual FRUs we can see the components just fine.
FRU Device Description : DBP (LUN 0, ID 210) <strong><------------------------------------- Same as /SYS/SASBP</strong> Board Mfg : 9615 HON HAI PRECISION CO. LTD SHENZHEN GUANGDONG CN Board Product : BD,SATA,LOUISE,8DSK_BKPLN Board Serial : 0226LHF-12120N0EHY Board Part Number : 511-1435-02 Board Extra : Rev 05 FRU Device Description : PDB (LUN 0, ID 211) Board Mfg : 9615 HON HAI PRECISION CO. LTD SHENZHEN GUANGDONG CN Board Product : BD,LOUISE,HPDB Board Serial : 0226LHF-1210F601EE Board Part Number : 541-4223-03 Board Extra : Rev 51 FRU Device Description : MB/RISER2 (LUN 0, ID 224) Board Mfg : 5030 CELESTICA CORP. SRIRACHA CHONBURI TH Board Product : BD,NON-XAUI RISER Board Serial : 1005LCB-1222B90YNL Board Part Number : 541-4085-04 Board Extra : Rev 50
CauseThis is most likely a temporary communication loss between the SP and the system SolutionClear the faults and reset the SP
References<BUG:18356258> - SPARC T5-2: MULTIPLE COMPONENTS REPORTS CORRUPTED FRUID SY<NOTE:1168559.1> - ILOM-8000-2V - FRUID contents are corrupt <NOTE:1331308.1> - SPARC T3-2 Current Product Issues Attachments This solution has no attachment |
||||||||||||||||||
|