1904125.1
:
CMUL Faulted with Power Issues ( Error Messages 01910d00, 01919220, 018f0001 )
Related Items |
- Fujitsu M10-1
- Fujitsu M10-4S
- Fujitsu M10-4
|
Related Categories |
- PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: Fujitsu M10
|
In this Document
Created from <SR 3-9149100781>
Applies to:
Fujitsu M10-4S - Version All Versions and later
Fujitsu M10-1 - Version All Versions and later
Fujitsu M10-4 - Version All Versions and later
Sun SPARC Sun OS
Symptoms
Diagnostic codes: 01910d00, 01919220, 018f0001
Sample errors from showlogs error:
Date: Jun 26 15:55:17 HKT 2014
Code: 80002008-0052020000ff0000ff-018f00010000000000000000
Status: Alarm Occurred: Jun 26 15:55:17.188 HKT 2014
FRU: /BB#0/CMUL
Msg: Power-off failure
Diagnostic Code:
00000200 00000000 0000
00000000 00000000 0000
00000000 00000000 0000
00202728 52202728 00000010 00000035
00000000 00000000 0000
Date: Jun 26 15:53:41 HKT 2014
Code: 40002000-0052020000ff0000ff-01910d000000000000000000
Status: Warning Occurred: Jun 26 15:53:41.491 HKT 2014
FRU: /BB#0/CMUL
Msg: Voltage out of range error
Diagnostic Code:
00000200 00000000 0000
00000000 00000000 0000
00000000 00000000 0000
4e756c6c 436f6d70 6f6e656e 74233237
00000000 00000000 0000
Date: Jun 26 15:53:34 HKT 2014
Code: 80002000-0060020000ff0000ff-019192200000000000000000
Status: Alarm Occurred: Jun 26 15:53:34.292 HKT 2014
FRU: /BB#0/CMUL
Msg: Insufficient PUMP rotation speed
Diagnostic Code:
00000001 00000000 0000
00000000 00000000 0000
00000000 00000000 0000
23323531 39313536 38340000 00000000
00000000 00000000 0000
Sample errors from showlogs monitor:
Jun 26 15:55:28 xscf Alarm: /BB#0/CMUL:SCF:Power-off failure
Jun 26 15:54:35 xscf Warning: /BB#0/CMUL:SCF:Voltage out of range error
Jun 26 15:54:34 xscf Alarm: /BB#0/CMUL:SCF:Insufficient PUMP rotation speed
Sample showstatus:
* BB#00 Status:Deconfigured;
* CMUL Status:Faulted;
* CPU#0 Status:Deconfigured;
* CPU#1 Status:Deconfigured;
* MEM#00A Status:Deconfigured;
* MEM#01A Status:Deconfigured;
* MEM#02A Status:Deconfigured;
* MEM#03A Status:Deconfigured;
* MEM#04A Status:Deconfigured;
* MEM#05A Status:Deconfigured;
* MEM#06A Status:Deconfigured;
* MEM#07A Status:Deconfigured;
* PSUBP Status:Deconfigured;
Changes
USB DVD device is attached to the USB port and is not powered by an external source.
Cause
The errors can be caused by an external USB DVD drive being powered by the USB port.
This specific drive has a max of 7.5W and the USB 2.0 spec is a max of .5A
Solution
As stated in the "Operation and Administration Guide":
Use a dedicated AC adapter to supply power to the externally connected DVD drive.
The recommended DVD drive and AC adapter is Oracle option 7106761 External USB DVD drive with AC adapter.
References
<NOTE:1534033.1> - M10-power.power-off - A fault occurred when the XSCF tried to turn off power to a DDC
<BUG:19072134> - THREE CMULS REPLACED FOR ERROR 018F0001
Attachments