![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1903893.1 : SL150 - Library Does Not Recognize the Barcode on the Tape Cartridge, the Media Type is Unknown
In this Document
Created from <SR 3-9264421721> Applies to:StorageTek SL150 Modular Tape Library - Version All Versions to All Versions [Release All Releases]LTO Tape Drive - Version All Versions and later Information in this document applies to any platform. Spectra Logic cartridge label. SymptomsSL150: library doesn't recognize the barcode, the media type is unknown. ChangesNew imported cartridge. CauseOne extra character is added after media domain and type. The below photo contain 9 characters and 2 asterisks as *TB0001L6P* Special character on volser label. SolutionReplace barcode label. References<NOTE:1016189.1> - Oracle/STK Libraries - Not Able to Read Non-Supported Barcode/Volser Labels - Specifications on Supported LabelsAttachments This solution has no attachment |
||||||||||||||||||||
|