In this Document
Symptoms
Cause
Solution


Applies to:

Sun Storage 6780 Array - Version All Versions and later
Sun Storage 6540 Array - Version All Versions and later
Sun Storage 2530-M2 Array - Version Not Applicable and later
Sun Storage 2540-M2 Array - Version Not Applicable and later
Sun Storage 6140 Array - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Sun Storage Common Array Manager (CAM) reports an open alarm against a Sun Storage 2500-M2 or 6000 array for a NET_SETUP_ERROR.  In this example, the alarm is opened on a Sun Storage 6780.

Event Code         : 80.66.1077
Event Type         : 6780.ProblemEvent.REC_NET_SETUP_ERROR
Severity           : 0
Sample Description : Network setup error detected on controller {0}.
Probable Cause     : Both of the ethernet ports on a single controller have been
                     configured to use the same subnet.
Recommended Action : Change the ethernet configuration so that the ports on a
                     single controller are on different subnets


Cause

As indicated by the alarm, both Ethernet ports on a single RAID controller have been configured on the same subnet. You can view this in two places:

  • CAM > Storage Array > Physical Devices > Controllers > Controller A(B) > Ethernet Port 1 and Ethernet Port 2.

  • The storageArrayProfile.txt file of the supportdata. For example:

Ethernet port: 1
MAC address: 00:a0:b8:xx:xx:xx
Network configuration: Static
IP address: 135.xx.xx.xx
Subnet mask: 255.255.252.0
Gateway: 135.xx.xx.xx

Ethernet port: 2
MAC address: 00:a0:b8:xx:xx:xx
Network configuration: Static
IP address: 135.xx.xx.xx
Subnet mask: 255.255.252.0
Gateway: 135.xx.xx.xx

 

Solution

Do not use Ethernet Port 2. When managing the array with CAM, you must only use Ethernet Port 1 for OOB communication. Ethernet Port 2 must be unconfigured in CAM, and unplugged from any switch. While the error message suggests that subnets are involved, in fact Ethernet Port 2 should never be configured or connected.

CAM > Storage Array > Physical Devices > Controllers > Controller A(B) > Ethernet Port 1 and Ethernet Port 2.

Ethernet port 2 is reserved for onsite diagnostics and Field Engineers to connect using Field Tools. 

 

 

Do you still have questions?  You can use My Oracle Support Communities.  Communities put you in touch with industry professionals like yourself.  They are monitored by Oracle support engineers, so you can expect reliable and correct answers.  Ask questions and see what others are asking about in the Disk Storage 2000, 3000, 6000 RAID Arrays & JBODs Community.

 