Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1901433.1
Update Date:2014-06-26
Keywords:

Solution Type  Problem Resolution Sure

Solution  1901433.1 :   Fujitsu M10-4/M10-4S Power Supply Interlocking Issue  


Related Items
  • Fujitsu M10-4S
  •  
  • Fujitsu M10-4
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: Fujitsu M10
  •  




In this Document
Symptoms
Cause
Solution


Applies to:

Fujitsu M10-4S - Version All Versions and later
Fujitsu M10-4 - Version All Versions and later
Information in this document applies to any platform.

Symptoms

  • Symptom1
    • Any of the following Remote Cabinet Interface over LAN (RCIL) control commands fail with "Controller response timeout".
      • setremotepwrmgmt(8)
      • getremotepwrmgmt(8)
      • clearremotepwrmgmt(8)
      • showremotepwrmgmt(8)
  • Symptom2
    • External I/O devices and/or Remote Power Distribution Unit (PDU) in the RCIL group are not controled by the power supply interlocking feature even if the SPARC M10-4/4S is powered on.

The system may not be able to start because a necessary SPARC M10 and/or an external I/O device(s) are not powered on by the power supply interlocking feature.

Cause

This problem only affects the Fujitsu M10-4 and M10-4S running XCP2220.

This problem is caused by an XSCF firmware bug. 

Because the process that supports the RCIL function does not initiate correctly, the power supply interlocking feature and the related commands do not work correctly.

Solution

There is no effective workaround.

Problem is fixed in XCP2221.

Please apply XCP2221 or higher.

 

or go to XCP2210.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.