![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1901389.1 : KMS 1.x - "Not Enough Raw Keys to Complete Operation; 0 available, 3 required" Error Message
In this Document
Created from <SR 3-9187820971> Applies to:Sun StorageTek Crypto Key Management System - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsAfter replacing tape drive, the KMS 1.x system is reporting the following error: CauseNot Enough Raw Keys to complete operation; 0 available, 3 required error message received when attempting to encrypt a replacement drive. Solution1) From command line, login as kmsadmin and from /opt/SUNWkms/app/mars run the following command: ./mkkeys -k 2
*** 1. Log in to the application using an Administrator login and password. 4. In the Import Keys Directory*, enter: /export/home/kms/mnt_cd *** The customer or FE can then proceed with encrypting the tape drive via the following procedure:
Attachments This solution has no attachment |
||||||||||||||||||
|