Created from <SR 3-9173629501> Applies to:Exadata X3-2 Hardware - Version All Versions and laterExadata X4-2 Hardware - Version All Versions and later Enterprise Manager for Exadata - Version 12.1.0.1.0 to 12.1.0.6.0 [Release 12.1] Information in this document applies to any platform. SymptomsWhen attempting to discover the Exadata rack, the Infiniband (IB) targets are discovered with the wrong host names. For example the resulting names are truncated: exadbprod01sw#-ib
CauseDocumentation bug for IB: Bug 18109470 - Incorrect Node Description info in Installation Guide All host names must be under 17 characters in length, and this is now stated in the IB documentation. SolutionChange the names of the IB switches to be under 17 characters using <Document 1464355.1> How To Change Host Name On Infiniband Switches. Then rediscover the rack. References<BUG:18109470> - INCORRECT NODE DESCRIPTION INFO IN INSTALLATION GUIDE<NOTE:1464355.1> - How To Change Host Name On Infiniband Switches Attachments This solution has no attachment |
||||||||||||
|