Solution Type Problem Resolution Sure Solution 1683072.1 : Pillar Axiom - What to do when you receive the event "Slammer Control Unit Recovery Succeeded"
In this Document
Applies to:Pillar Axiom 600 Storage System - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsThis event will occur when a slammer CU warmstarts and is able to recover. Event logs will look similar to this: 2014-06-07T20:17:07+02:00 Informational SlammerControlUnitRecoverySucceeded Slammer1 CU-1 Or in Release 5, PCP_EVT_SLAMMER_WARMSTART_COMPLETE. CauseSlammer Control Unit Recovery Succeeded is reported when a warmstart of a slammer CU occurs and is able to recover. These events are generated for one of the following reasons: 1) S/W has initiated the warmstart to correct the problem. 2) Occurs during a S/W upgrade. 3) Manually executed via CLI.
SolutionIf this is the only event reported, and the system is showing all NORMAL, there is no action to take. The SR that would normally be generated will be closed automatically. If the system is not normal, please contact support for assistance.
It is recommended to always be at the latest release, please review the following document to determine the current release:
KM <Document 1422199.1> How to Find Pillar Axiom Firmware and Patches in My Oracle Support. Attachments This solution has no attachment |
||||||||||||||||||
|