Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1681561.1
Update Date:2015-12-15
Keywords:

Solution Type  Problem Resolution Sure

Solution  1681561.1 :   After IXP Server Upgrade to PIC 9.0.3 and 9.0.4 Some Sessions are Not Recovering  


Related Items
  • Oracle Communications Performance Intelligence Center (PIC) Software
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec PIC
  •  




In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 2-9400132>

Applies to:

Oracle Communications Performance Intelligence Center (PIC) Software - Version 9.0.3 to 9.0.4 [Release 9.0]
Tekelec

Symptoms

After IXP server upgrade, some sessions are not recovering. No particular error message visible from ProTrace application GUI beside session end time not updating.

Changes

IXP server was just upgraded.

Cause

IxpForward might be stuck in deadthread state and is not recovering automatically.

This can be confirmed by look at IxpForward log which is stuck on following message:

1008:153244.048  TR-V  Dead thread detected: 0xb6774b90 (MonitoringManager1) - Subsystem:  [5618/CcMain.cpp:357]
1008:153245.050  TR-V  See details in /var/TKLC/ixp/run/proc/IxpForward/deadthread.IxpForward.131008153245 [5618/CcMain.cpp:412]

Solution

  1. Connect on IXP server as cfguser
  2. Kill IxpForward process:
    pm.kill -9 IxpForward
  3. Verify IxpForward logs. New message should appear and no new "deadthread" message should be visible

Issue will not reoccur outside an upgrade context, so it is a definitive workaround.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.